Ni 9411 - To setup the 9411 as an encoder you will need to create an Axis Interface VI and use gearing. I recommend getting started with the 9401 encoder example. I have attached it below since in 2010 the example was removed (CAR . 258565). You will need to open the FPGA block diagram and modify the digital I/O to read from 9411 lines instead …

 
7 NI 9411 Operating Instructions and Specifications. measures whether the difference between the DIa and DIb pins is greater than or less than the digital logic levels. If the difference between the pins is within the input high range, the channel registers as high. If the difference between the pins is within the input low range, …. Nothing else youtube

Product Description. C Series Digital Module. Model Number(s). NI-9411. Product Category. Electrical equipment for measurement, control, and laboratory use ...Aug 10, 2016 ... Re: NI 9411 & NI 9402 not working together (Error -50103 ("The specified resource is reserved")) ... Thankyou for your kind reply. I took your ....Overview. The NI 9411 is a C Series module designed for 6-channel, 500 ns differential/single-ended digital inputs. Each channel is compatible with ±5 V to 24 V …Oct 11, 2012 · Physical Connections to use 4 counters with NI 9411 in cDAQ 9178 chassis. 10-11-2012 12:44 PM. Currently I have a NI 9411 module in a cDAQ 9178 chassis. I am using 2 of the counters to read frequency measurements. From the NI 9411 pinout diagram (see pdf file attached to this post), these are the connections I made: NICRIO-9411: 200Kb / 3P: CompactRIO Digital Input and Counter/Timer Modules Omron Electronics LLC: H8GN: 570Kb / 26P: Preset Counter/Timer H8GN C-61 National Instruments Co... NI940X: 1Mb / 6P: C Series Digital Output and Relay Modules Mitsubishi Electric Sem... M51849L: 114Kb / 4P: COUNTER TIMER …This page documents all the applicable standards and certifications for the NI-9411 and provides downloadable certifications. The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis. This article explains which NI C Series modules you can use to access the counters or timers on your CompactDAQ (cDAQ) chassis or controller's backplane. Use this article if you want to use a quadrature encoder or other sensor to measure frequency, period, pulse width, semi period, two edge separation, … Overview. The NI 9411 is a C Series module designed for 6-channel, 500 ns differential/single-ended digital inputs. Each channel is compatible with ±5 V to 24 V signals. The NI 9411 works with industrial logic levels and signals to directly connect to a wide array of industrial switches, transducers, and devices. View and Download National Instruments NI 9411 getting started manual online. C Series Digital Module. NI 9411 control unit pdf manual download.Dear all, It is possible to use the NI 9411 for synchronous Serial Data reception? For example, let have a stream at 10kbps data rate (33.3us/bit clock), from a serial sensor continuously feeding bits of data, separated by some given "delimiter". Which would be the maximum data rate, if this ...Aug 21, 2023 ... NI 9411无需通过软件进行配置即可执行差分或单端测量。唯一的不同是传感器或转换器与模块之间的连接。 在差分模式下,NI 9411在DIa(正)和DIb(负)端口 ... The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis. NI-9411 Specifications. The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to COM unless otherwise noted. Caution. … NI‑9411 funziona con segnali e livelli logici industriali per la connessione diretta a un'ampia gamma di interruttori, trasduttori e dispositivi industriali. NI ‑9411 è un modulo digitale correlato in grado di effettuare operazioni di misura corrente, triggering e sincronizzazione quando è installato in uno chassis CompactDAQ. このマニュアル. 製品ドキュメント NI-9411 Specifications NI-9411 Specifications. NI-9411 Specifications. 更新日 2023-07-20. 4分で読める. NI-9411. Specifications. Definitions. Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Jun 9, 2010 · The encoder comes with four leads: +5V power, GND, Channel A and Channel B. Both Channel A and Channel B are logic output. Channel A and Channel B are connected to the DIO of NI-9401 which is mounted on cRIO. A standard VI for encoder counting is used and compiled under the FPGA environment. During the measurement, I observed that there are ... El NI‑9411 funciona con niveles lógicos y señales industriales para conectarse directamente a una amplia variedad de conmutadores, transductores y dispositivos industriales.El NI‑9411 es un módulo digital correlacionado, así que puede realizar medidas correlacionadas, disparo y sincronización al estar instalado en un chasis CompactDAQ.The NI 9411 channels share a common ground isolated from other modules in the system. Figure 1. NI 9411 Input Circuitry COM Vsup COM NI 9411 DIa +5 Vout DIb +5 V Reg Receiver Circuitry NI 9411 Specifications The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to COM unless ...The NI-9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI-9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.Aug 21, 2023 ... NI 9411无需通过软件进行配置即可执行差分或单端测量。唯一的不同是传感器或转换器与模块之间的连接。 在差分模式下,NI 9411在DIa(正)和DIb(负)端口 ...Amazon Alexa will be the foundation of BMW's next-generation voice assistant, the companies announced at an Amazon event. Amazon Alexa will be the foundation of BMW’s next-generati...Jun 10, 2016 · PWM measurement with NI 9411 is never zero. 07-10-2013 09:38 PM. I am using the NI9411 DI module on a cRIO 9074 to measure a 1 kHz PWM signal. I created an empty project, set the mode of the module to "counter" "pulse width measurement" "High pulse" and "disabled" input filter. For taking a first look at the measured values i used the NI ... The NI 9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI 9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in an NI CompactDAQ chassis. This document describes encoder theory, the basics of measuring an encoder, and options for measuring encoders use NI hardware. Encoder and Applications Overview An encoder is an electromechanical device that can measure motion or position. Most encoders use optical sensors to provide electrical signals in the form of pulse … Connect the device to the DIa and DIb pins on the NI 9411. The NI 9411 measures whether the difference between the DIa and DIb pins is greater than or less than the digital logic levels. If the difference between the pins is within the input high range, the channel registers as high. NI 9411 AI-DI synchronization. 06-27-2011 05:30 AM. I am using a cDAQ-9188 with two analog input modules (9234, 9215) and one digital input module 9411. I need to measure the frequency of a TTL signal with the 9411 and to synchronize this acquisition with the ones of the analog modules.NI 9411无需通过软件进行配置即可执行差分或单端测量。. 唯一的不同是传感器或转换器与模块之间的连接。. 在差分模式下,NI 9411在DIa(正)和DIb(负)端口之间进行差分测量。. 硬件采用两个输入的差值,并确定它是高电平(300 mV至24 V之间)还是低电平(-300 mV ... NI-9411 安全性、環境與法規資訊. NI-9411 產品認證. NI-9411 波動性聲明. 您可以提出維修申請、安排校準時間,或取得技術支援。. 可能需具備有效的服務計畫協定。. 申請支援. 搜尋由 NI 工程師撰寫而成的常見問題集,以及常見錯誤的疑難排解秘訣。. 知識庫. 提問 ... Everything LGBTQ travelers need to do in Tokyo and the gay Ni-Chome neighborhood, including where to stay, where to eat, and the best bars. Compared to any other city in Japan, Tok...The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.Both can be used with the NI 9411. You can check the device pinout in NI MAX or find it in the NI 9411 Getting Started Guide to notice it has two inputs per channel, one positive and one negative, also explained in Using the NI 9411 Inputs as Differential or Single-Ended. Connecting a Differential Encoder (two wires per channel)Specifications. 2022-08-19. NI-9411. DSUB connectivity. CompactDAQ counter compatibility. 60 V DC, CAT I, channel-to-earth isolation. The NI-9411 works with industrial logic levels …こんにちは . 早速ですが、ロータリーエンコーダの出力信号をni-9411に取り込んで、角度情報を収集したいと考えています。This article explains which NI C Series modules you can use to access the counters or timers on your CompactDAQ (cDAQ) chassis or controller's backplane. Use this article if you want to use a quadrature encoder or other sensor to measure frequency, period, pulse width, semi period, two edge separation, …The alternative would be to use the NI-9411's differential digital inputs to measure the encoder's differential outputs. However, differential encoders can be used in the same way that a single-ended quadrature encoder is used. The A, B and Z index channels can be connected to the SOURCE, AUX and GATE pins on the DAQ counter.Zener, Hello! This KnowledgeBase article talks about how to reset the counter on the 9411.. Now, setting your counter to have a preset value is kind of tricky. Using property nodes you can set what number the counter will count too, along with that you can set it to count down instead of up, from that value (terminal count).Using the NI 9411 module with cDAQ-9178 to measure frequency. 07-23-2018 03:33 PM. I am using the NI 9411 module paired with the cDAQ 9178 to read a frequency signal. I have successfully been able to read the frequency of a signal from a function generator by using the PFI 0 and PFI 1 channels on my cDAQ … NI-DAQmx. Provides support for NI data acquisition and signal conditioning devices. NI-VISA. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. NI-488.2. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. We recently asked our TPG Lounge audience to share the best points and miles redemptions they've made for friends, family and other people. We recently asked our TPG Lounge readers...Apr 24, 2023 · To power the encoder using the 5 V pins on the NI 9411 module, you have to plug in an external power supply to the Vsupp and COM terminals on the NI 9411. Depending on your encoder, it might be needed to to add a pull-up or pull-down resistors to get appropriate measurements. Those resistors are needed to make sure the appropriate voltage ... The NI 9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI 9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis. Kit Contents. Dear all, I am using a NI 9178 rack containing 2x NI 9222 analog acquisition cards and 1 NI 9411 digital acquisition card. These cards acquire data simulanuously and continuously at a rate of 108 kS/s.I wrote an application in C# that reads data from the cards sequentially in chunks of 27000 samples (0.25 sec) per read-out.NI 9411. 6-Channel Differential Digital Input Module. Français. Deutsch. ni.com/manuals. This document describes how to use the National Instruments 9411 and includes …The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.Consider using counters: NI 9401 NI 9423 NI 9411: The PXIe-2461, NI 9401, NI 9423, or NI 9411 can be suitable replacement depending on the application requirements. Contact NI for any questions about the compatibility. SCC-LP01: PXIe-4302 PXIe-4303: NI 9207 NI 9209 NI 9218 NI 9239 SCC-LP02: PXIe-4302 PXIe-4303: NI …Jun 14, 2010 ... Using 9411 Scan Mode cRIO-9074 ... Hi,. I am using a NI9411 Incremental Differential Input Module under cRIO-9074 with Scan Mode, but I have ...NI-9411 Issue Details When I measure the voltage between the common line and a digital input on my NI 9411 digital input module I see roughly 1.5V. Why is this? Solution The 9411 doesn't have internal pull-up or pull-down resistors that pull the digital lines high or low. ...NI-9411. 2770-779005-01. Standard Package: 1: Co-Browse. By using the Co-Browse feature, you are agreeing to allow a support representative from DigiKey to view your browser remotely. When the Co-Browse window opens, give the session ID that is located in the toolbar to the representative.Physical Connections to use 4 counters with NI 9411 in cDAQ 9178 chassis. 10-11-2012 12:44 PM. Currently I have a NI 9411 module in a cDAQ 9178 chassis. I am using 2 of the counters to read frequency measurements. From the NI 9411 pinout diagram (see pdf file attached to this post), these are the connections …The NI 9411 works with industrial logic levels and signals to directly connect to a wide array of industrial switches, transducers, and devices. The NI 9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in an NI CompactDAQ chassis. Recommended …Both can be used with the NI 9411. You can check the device pinout in NI MAX or find it in the NI 9411 Getting Started Guide to notice it has two inputs per channel, one positive and one negative, also explained in Using the NI 9411 Inputs as Differential or Single-Ended. Connecting a Differential Encoder (two wires per channel)Hi to all, I have an omega TQ514 sensor and I want to connect it to NI 9411 and NI cDAQ 9178 for measuring RPM. My problem is I dont know the right connection for the encoder to NI 9411 and also the programming in labview. When i tried it says that I must add external clock source and I dont know wh...The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.掲題の通り、ni9411へのエンコーダ信号の接続について不明点がありますので ご存知の方がおられましたらアドバイスをいただければと思います。 エンコーダ情報は安川のサーボΣ-Ⅴの+a相・-a相・+b相・-b相を ni9411へ接続しようと考えております。 接続としては …Apr 5, 2023 ... NI-9401; NI-9402; NI-9403; NI-9411. Issue Details. I have a quadrature encoder (Sick DBS36E-S3AP02500 with 5V TTL outputs) connected to the ...8 DIO, 5 V/TTL, Bidirectional, 100 ns. This document explains how to connect to the NI 9401. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9401. The other components in the system might not meet the same safety ratings.Aug 21, 2023 ... NI 9411无需通过软件进行配置即可执行差分或单端测量。唯一的不同是传感器或转换器与模块之间的连接。 在差分模式下,NI 9411在DIa(正)和DIb(负)端口 ...Zener, Hello! This KnowledgeBase article talks about how to reset the counter on the 9411.. Now, setting your counter to have a preset value is kind of tricky. Using property nodes you can set what number the counter will count too, along with that you can set it to count down instead of up, from that value (terminal count).Cumberland Island is the largest of the Sea Islands off the coast of the Southeastern United States. President Richard Nixon established... Share Last Updated on January 11, 2023 C...NICRIO-9411: 200Kb / 3P: CompactRIO Digital Input and Counter/Timer Modules Omron Electronics LLC: H8GN: 570Kb / 26P: Preset Counter/Timer H8GN C-61 National Instruments Co... NI940X: 1Mb / 6P: C Series Digital Output and Relay Modules Mitsubishi Electric Sem... M51849L: 114Kb / 4P: COUNTER TIMER …Steps to Reproduce: 1. Connect NI 9411 to cDAQ-9189. 2. Create counter channel with DAQmxCreateCILinEncoderChan 3. Configure sample clock 4. Register ni-daqmx. niの集録および信号調整デバイスをサポートします。 ni-visa. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488.2. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。 Feb 16, 2024 · The NI-9411 is available with conformal coating for additional protection in corrosive and condensing environments, including environments with molds and dust. In addition to the environmental specifications listed in the NI-9411 Safety, Environmental, and Regulatory Information, the NI-9411 with conformal coating meets the following ... Oct 11, 2012 · Physical Connections to use 4 counters with NI 9411 in cDAQ 9178 chassis. 10-11-2012 12:44 PM. Currently I have a NI 9411 module in a cDAQ 9178 chassis. I am using 2 of the counters to read frequency measurements. From the NI 9411 pinout diagram (see pdf file attached to this post), these are the connections I made: Hi, I am using a NI9411 Incremental Differential Input Module under cRIO-9074 with Scan Mode, but I have noticed that some problems are arising. My application need two encoder and we select two differential encoders with 1024pulses/rev. I have configured the NI9411 in quadrature Mode, so I can ...Feb 16, 2024 · The NI-9411 is available with conformal coating for additional protection in corrosive and condensing environments, including environments with molds and dust. In addition to the environmental specifications listed in the NI-9411 Safety, Environmental, and Regulatory Information, the NI-9411 with conformal coating meets the following ... Nov 27, 2023 ... I would like to take a counter or frequency measurement with an NI 94xx digital input module in a CompactRIO(cRIO)using Specialty Digital ...Medicine Matters Sharing successes, challenges and daily happenings in the Department of Medicine ARTICLE: MCU Overexpression Rescues Inotropy and Reverses Heart Failure by Reducin...I am measuring the shaft rpm using the encoder and feeding it to the 9411 card.Can the 9411 card display the shaft rpm? How the card can do this conversion?Should I use any other component to decode the digital input pulse?Options. I have some troubles with electrical noise (sometimes signal detected in absence of the real signal) while using NI 9411 with 24V single - ended device (which have own power supply). According to cover sheet I can connect Diff/Single Ended +/-5 to 24V signal to this module: From the user manual: Already put pull-down resistor …Download. File Size: 451Kbytes. Page: 5 Pages. Description: C Series Digital Input and Counter/Timer Modules. Manufacturer: National Instruments Corporation.This document describes encoder theory, the basics of measuring an encoder, and options for measuring encoders use NI hardware. Encoder and Applications Overview An encoder is an electromechanical device that can measure motion or position. Most encoders use optical sensors to provide electrical signals in the form of pulse …Description. This example shows how to use multiple NI-9411 C Series Digital Modules in LabVIEW FPGA Interface programming mode. You will need to use LABVIEW FPGA Interface programming mode instead of Scan Interface proramming mode because the CompactRIO Chassis supports only two slots for specialty digital functions in Scan …Apr 17, 2023 · Additionally, the example program was designed for a PXI-7811R PXI Digital Reconfigurable I/O Module FPGA and an R Series expansion chassis with a NI-9411 DI module in slot 1. How-Separate-2 Additional Information Additional-Separate-1. The attached VI can easily be modified to run on any other CompactRIO FPGA hardware. Additional-Separate-2 ... Aug 3, 2023 ... 대부분의 NI-DAQ 카드는 차동 엔코더 측정을 지원하지 않습니다. NI-9411의 차동 디지털 입력을 사용하여 엔코더의 차동 출력을 측정하는 방법도 있습니다 ... The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis. Visit http://bit.ly/cbx7cq to learn more about NI X SeriesLearn how you can use a USB X Series device and LabVIEW to measure a quadrature encoder and generat...NI 9411无需通过软件进行配置即可执行差分或单端测量。. 唯一的不同是传感器或转换器与模块之间的连接。. 在差分模式下,NI 9411在DIa(正)和DIb(负)端口之间进行差分测量。. 硬件采用两个输入的差值,并确定它是高电平(300 mV至24 V之间)还是低电平(-300 mV ...Introduction. Not all digital modules support special digital functions. Specialty digital functions are: Counter input. Counter-driven output. Pulse-width modulation (PWM) output. Quadrature encoder input. The following table outlines what modules do support specialty digital and what specific functions as of …Both can be used with the NI 9411. You can check the device pinout in NI MAX or find it in the NI 9411 Getting Started Guide to notice it has two inputs per channel, one positive and one negative, also explained in Using the NI 9411 Inputs as Differential or Single-Ended. Connecting a Differential Encoder (two wires per channel)Jun 14, 2010 ... Using 9411 Scan Mode cRIO-9074 ... Hi,. I am using a NI9411 Incremental Differential Input Module under cRIO-9074 with Scan Mode, but I have ...Chassis NI cDAQ9188; NI 9411; Quadrature Encoder . I want to make continuous buffered measurement of position reading from the quadrature encoder. I first set up a task in NI MAX: It works if I configure my signal as 1 Sample (On Demand). It doesn’t work if I change to Continuous Samples (Use digital input sample clock as the external sample ...Connecting an external power supply to the NI 9411 is optional, depending on your application. Page 13: Connecting A Differential Device To The Ni 9411 – Differential Device NI 9411 The NI 9411 compares the difference between DIa and DIb to the digital logic levels to determine if the signal is in the high range or low range.Product Description. C Series Digital Module. Model Number(s). NI-9411. Product Category. Electrical equipment for measurement, control, and laboratory use ...It sounds like you need to put a time-out on your VI so that if no pulses are detected in a period, then set the output to 0. Your VI only updates the 'Period 1' value on the rising edge of the 9411 Digital Input - so if there are no rising edges (because the pulse train has stopped) then it will always use the last value, hence the need for a time-out.I have had a look at the 9411 and 9423 modules but the pin outs only have connections for the positve digital input signal and a common per channel. The instrumentation I am trying to connect has 5 connections: Data +, Data -, Clk+, Clk -, and Ground. ... Use a NI 9871 (4-Port RS485/RS422 Serial Interface Module), which …Let's review the charts and indicators....NI In his first "Executive Decision" segment of Wednesday's Mad Money program, Jim Cramer spoke with Joe Hamrock, president and CEO of...Let's review the charts and indicators....NI In his first "Executive Decision" segment of Wednesday's Mad Money program, Jim Cramer spoke with Joe Hamrock, president and CEO of...Hi, I am using a NI9411 Incremental Differential Input Module under cRIO-9074 with Scan Mode, but I have noticed that some problems are arising. My application need two encoder and we select two differential encoders with 1024pulses/rev. I have configured the NI9411 in quadrature Mode, so I can ...The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.

Jun 10, 2016 · PWM measurement with NI 9411 is never zero. 07-10-2013 09:38 PM. I am using the NI9411 DI module on a cRIO 9074 to measure a 1 kHz PWM signal. I created an empty project, set the mode of the module to "counter" "pulse width measurement" "High pulse" and "disabled" input filter. For taking a first look at the measured values i used the NI ... . Richard pasma 2022

ni 9411

Cash for keys programs are offered by mortgage companies to allow homeowners a chance to avoid foreclosure. If your lender has a cash in exchange for keys program, you need to comp...The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis. The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis. NI‑9411 은 산업용 로직 레벨과 신호를 지원하며 광범위한 산업용 스위치, 트랜스듀서, 기타 디바이스에 직접 연결됩니다. NI‑9411 은 상호연관된 디지 털 모듈이므로, CompactDAQ 섀시에 설치하면 상호연관된 측정, 트리거링, 동기화를 수행할 수 있습니다.The biggest dilemma in retirement investing may be how hard it will be to grow our savings in the next decade. By clicking "TRY IT", I agree to receive newsletters and promotions f...こんにちは . 早速ですが、ロータリーエンコーダの出力信号をni-9411に取り込んで、角度情報を収集したいと考えています。El NI‑9411 funciona con niveles lógicos y señales industriales para conectarse directamente a una amplia variedad de conmutadores, transductores y dispositivos industriales.El NI‑9411 es un módulo digital correlacionado, así que puede realizar medidas correlacionadas, disparo y sincronización al estar instalado en un chasis CompactDAQ.DAQ sampling rate. 09-13-2011 07:24 PM. I am using NI 9411 (digital card) and NI 9203 (analog card). when I set sampling rate at 1000Hz, everything works fine. But when I set sampling rate to100kHz, no data recorded. I am wondering what is the maximum sampling rate for the harfware (When I use MAX to simulate, I do get some data recorded).Apr 24, 2023 · Wire the positive and negative A, B and Z outputs from the encoder as shown in the figure below. Connecting a Single-Ended Encoder (one wire per channel) Connect the A, B and Z terminals from the encoder to the positive channel inputs in the module. Leave any negative inputs unwired. NI 9402 LVTTL Input/ Output 4 16 MHz NI 9411 5 V Differential, 24 V Single Ended 6 Input 1 MHz NI 9421 8 30 V Input 10 kHz NI 9422 8 60 V Input 4 kHz NI 9423 8 30 V Input 1 MHz NI 9435 4 250 V Input 333 Hz NI 9437 8 250 V Input 10 kHz 2 | ni.com | NI 9361 Datasheet. NI C Series OverviewNI 9411 AI-DI synchronization. 06-27-2011 05:30 AM. I am using a cDAQ-9188 with two analog input modules (9234, 9215) and one digital input module 9411. I need to measure the frequency of a TTL signal with the 9411 and to synchronize this acquisition with the ones of the analog modules.how to measure pulses from 24v flow meter sensor with NI 9411. 05-11-2010 01:20 AM. I have a 24v pulses flow meter sensor, how is it possible to connect it to My NI 9411 ?.